| RZAG71N7V1B | RZAG71N2V1B | RZAG100N7V1B | RZAG100N2V1B | RZAG125N7V1B | RZAG125N2V1B | RZAG140N7V1B | RZAG140N2V1B | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dimensionet | Njësia | Lartësia | mm | 870 | 870 | 870 | 870 | 870 | 870 | 870 | 870 | |
| Gjerësia | mm | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |||
| Thellësia | mm | 460 | 460 | 460 | 460 | 460 | 460 | 460 | 460 | |||
| Pesha | Njësia | kg | 81 | 81 | 85 | 85 | 95 | 95 | 95 | 95 | ||
| Kompresori | Lloji | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues i mbyllur hermetikisht | |||||
| Diapazoni i funksionimit | Ftohje | Ambienti | Min. | °CDB | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 |
| Maks. | °CDB | 52 | 52 | 52 | 52 | 52 | 52 | 52 | 52 | |||
| Ngrohje | Ambienti | Min. | °CWB | -20 | -20 | -20 | -20 | -20 | -20 | -20 | -20 | |
| Maks. | °CWB | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | |||
| Niveli i fuqisë së zhurmës | Ftohje | dBA | 64 | 64 | 66 | 66 | 69 | 69 | 70 | 70 | ||
| Ngrohje | dBA | 68 (1) | 68 (1) | 71 (1) | 71 (1) | |||||||
| Niveli i presionit të zhurmës | Ftohje | Nom. | dBA | 46 | 46 | 47 | 47 | 49 | 49 | 50 | 50 | |
| Ngrohje | Nom. | dBA | 48 | 48 | 50 | 50 | 52 | 52 | 52 | 52 | ||
| Agjenti ftohës | Lloji | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | |||
| Mbushja | kg | 3.2 | 3.20 | 3.2 | 3.20 | 3.7 | 3.70 | 3.7 | 3.70 | |||
| GWP | 675 | 675 | 675 | 675 | 675 | 675 | 675 | 675 | ||||
| Mbushja | tCO2Eq | 2.16 | 2.16 | 2.16 | 2.16 | 2.5 | 2.50 | 2.5 | 2.50 | |||
| Lidhjet e tubacioneve | Lëngu | Dia. jasht. | mm | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
| Gazi | Dia. jasht. | mm | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | ||
| Gjatësia e tubacioneve | Maks. | OU - IU | m | 55 | 55 | 85 | 85 | 85 | 85 | 85 | 85 | |
| Sistemi | Ekuivalent | m | 75 | 75 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Pa ngarkesë | m | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |||
| Mbushje shtesë me agjent ftohës | kg/m | Shihni manualin e instalimit | Shihni manualin e instalimit | Shihni manualin e instalimit | Shihni manualin e instalimit | Shihni manualin e instalimit | Shihni manualin e instalimit | Shihni manualin e instalimit | Shihni manualin e instalimit | |||
| Ndryshimi i nivelit | IU - OU | Maks. | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| IU - IU | Maks. | m | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | ||
| Aksesore Standarde | Installation manual | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
| Refrigerant label for F-gas regulation | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| General safety precautions | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| Peel off F-gas label | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| Tie-wraps | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||||
| Furnizimi me energji | Faza | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | |||
| Frekuenca | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |||
| Tensioni | V | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | |||
| Rryma - 50 Hz | Amperët maksimalë të siguresës (MFA) | A | 20 | 20 | 32 | 32 | 32 | 32 | 32 | 32 | ||
| Kompresori | Lloji | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues i mbyllur hermetikisht | |||||||||
| Shënime | (1) - Sipas ENER Lot 21 | (1) - Sipas ENER Lot 21 | (1) - Sipas ENER Lot 21 | (1) - Sipas ENER Lot 21 | ||||||||