Tabela e specifikimeve për ETVH-D6VG / EPRA014-018DV

ETVH16S18DA6VG / EPRA14DAV3 ETVH16S23DA6VG / EPRA14DAV3 ETVH16S18DA6VG / EPRA16DAV3 ETVH16S23DA6VG / EPRA16DAV3 ETVH16S18DA6VG / EPRA18DAV3 ETVH16S23DA6VG / EPRA18DAV3
Indoor unit ETVH16S18DA6V ETVH16S23DA6V ETVH16S18DA6V ETVH16S23DA6V ETVH16S18DA6V ETVH16S23DA6V
Kapaciteti ngrohës Min. kW 3.70 (1) 3.70 (1) 3.96 (1) 3.96 (1) 4.40 (1) 4.40 (1)
  Nom. kW 5.69 (2) 5.69 (2) 9.00 (2) 9.00 (2) 9.00 (2) 9.00 (2)
  Maks. kW 10.18 (1) 10.18 (1) 10.91 (1) 10.91 (1) 12.12 (1) 12.12 (1)
Fuqia në hyrje Ngrohje Min. kW 0.88 (5) 0.88 (5) 0.95 (5) 0.95 (5) 1.05 (5) 1.05 (5)
    Nom. kW 1.22 (2) 1.22 (2) 1.80 (2) 1.80 (2) 1.80 (2) 1.80 (2)
    Maks. kW 2.09 (5) 2.09 (5) 2.24 (5) 2.24 (5) 2.49 (5) 2.49 (5)
  Domestic hot water from 10°C to 50°C Nom. kWh 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6)
Heat up time from 10°C to 50°C hr 1h02min at 7°C ambient temperature 1h13min at 7°C ambient temperature 1h02min at 7°C ambient temperature 1h13min at 7°C ambient temperature 1h02min at 7°C ambient temperature 1h13min at 7°C ambient temperature
COP 4.67 (2) 4.67 (2) 5.00 (2) 5.00 (2) 5.00 (2) 5.00 (2)
Ngrohje e ujit të ngrohtë në shtëpi Të përgjithshme Profili i deklaruar i ngarkesës   L XL L XL L XL
  Klimë mesatare Kategoria e efikasitetit të energjisë të ngrohjes së ujit   A A A A A A
Ngrohja e ambientit Dalja e ujit klimë mesatare 55°C Të përgjithshme SCOP   3.58 3.58 3.58 3.58 3.58 3.58
      Klas. efikasitetit të ngrohjes sezonale të ambientit   A++ A++ A++ A++ A++ A++
      ηs (Efikasiteti sezonal i ngrohjes së ambientit) % 140 140 140 140 140 140
  Dalja e ujit klimë mesatare 35°C Të përgjithshme SCOP   4.51 4.51 4.51 4.51 4.51 4.51
      Klas. efikasitetit të ngrohjes sezonale të ambientit   A+++ A+++ A+++ A+++ A+++ A+++
      ηs (Efikasiteti sezonal i ngrohjes së ambientit) % 177 177 177 177 177 177
Shënime (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C
  (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB (3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB (3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB (3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB (3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB (3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB
  (4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB (4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB (4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB (4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB (4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB (4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB
  (5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511
  (6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147.
  (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë