ETVH16S18DA6VG / EPRA14DAV3 |
ETVH16S23DA6VG / EPRA14DAV3 |
ETVH16S18DA6VG / EPRA16DAV3 |
ETVH16S23DA6VG / EPRA16DAV3 |
ETVH16S18DA6VG / EPRA18DAV3 |
ETVH16S23DA6VG / EPRA18DAV3 |
Indoor unit |
ETVH16S18DA6V |
ETVH16S23DA6V |
ETVH16S18DA6V |
ETVH16S23DA6V |
ETVH16S18DA6V |
ETVH16S23DA6V |
Kapaciteti ngrohës |
Min. |
kW |
3.70 (1) |
3.70 (1) |
3.96 (1) |
3.96 (1) |
4.40 (1) |
4.40 (1) |
|
Nom. |
kW |
5.69 (2) |
5.69 (2) |
9.00 (2) |
9.00 (2) |
9.00 (2) |
9.00 (2) |
|
Maks. |
kW |
10.18 (1) |
10.18 (1) |
10.91 (1) |
10.91 (1) |
12.12 (1) |
12.12 (1) |
Fuqia në hyrje |
Ngrohje |
Min. |
kW |
0.88 (5) |
0.88 (5) |
0.95 (5) |
0.95 (5) |
1.05 (5) |
1.05 (5) |
|
|
Nom. |
kW |
1.22 (2) |
1.22 (2) |
1.80 (2) |
1.80 (2) |
1.80 (2) |
1.80 (2) |
|
|
Maks. |
kW |
2.09 (5) |
2.09 (5) |
2.24 (5) |
2.24 (5) |
2.49 (5) |
2.49 (5) |
|
Domestic hot water from 10°C to 50°C |
Nom. |
kWh |
2.57 (6) |
2.85 (6) |
2.57 (6) |
2.85 (6) |
2.57 (6) |
2.85 (6) |
Heat up time from 10°C to 50°C |
hr |
1h02min at 7°C ambient temperature |
1h13min at 7°C ambient temperature |
1h02min at 7°C ambient temperature |
1h13min at 7°C ambient temperature |
1h02min at 7°C ambient temperature |
1h13min at 7°C ambient temperature |
COP |
4.67 (2) |
4.67 (2) |
5.00 (2) |
5.00 (2) |
5.00 (2) |
5.00 (2) |
Ngrohje e ujit të ngrohtë në shtëpi |
Të përgjithshme |
Profili i deklaruar i ngarkesës |
|
L |
XL |
L |
XL |
L |
XL |
|
Klimë mesatare |
Kategoria e efikasitetit të energjisë të ngrohjes së ujit |
|
A |
A |
A |
A |
A |
A |
Ngrohja e ambientit |
Dalja e ujit klimë mesatare 55°C |
Të përgjithshme |
SCOP |
|
3.58 |
3.58 |
3.58 |
3.58 |
3.58 |
3.58 |
|
|
|
Klas. efikasitetit të ngrohjes sezonale të ambientit |
|
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
|
|
|
ηs (Efikasiteti sezonal i ngrohjes së ambientit) |
% |
140 |
140 |
140 |
140 |
140 |
140 |
|
Dalja e ujit klimë mesatare 35°C |
Të përgjithshme |
SCOP |
|
4.51 |
4.51 |
4.51 |
4.51 |
4.51 |
4.51 |
|
|
|
Klas. efikasitetit të ngrohjes sezonale të ambientit |
|
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
|
|
|
ηs (Efikasiteti sezonal i ngrohjes së ambientit) |
% |
177 |
177 |
177 |
177 |
177 |
177 |
Shënime |
(1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C |
(1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C |
(1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C |
(1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C |
(1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C |
(1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C |
|
(2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
|
(3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB |
(3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB |
(3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB |
(3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB |
(3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB |
(3) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB |
|
(4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB |
(4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB |
(4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB |
(4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB |
(4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB |
(4) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB |
|
(5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 |
(5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 |
(5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 |
(5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 |
(5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 |
(5) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 |
|
(6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. |
(6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. |
(6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. |
(6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. |
(6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. |
(6) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. |
|
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë |
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë |
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë |
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë |
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë |
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë |